HTHP Consistometer, 25,000 PSI, 400°F
#120-00: Single Cell
#120-00-DAS: Single Cell with Data Acquisition System
#120-05: Dual Cell
#120-05-DAS: Dual Cell with Data Acquisition System
HTHP Consistometer, 40,000 PSI, 600°F
#120-10: Single Cell
#120-10-DAS: Single Cell with Data Acquisition System
#120-15: Dual Cell
#120-15-DAS: Dual Cell with Data Acquisition System
During cementing operations, the time required
for a cement slurry to set is of primary concern.
Under an ideal situation, minimal time would be
required to successfully pump the slurry, which
immediately upon placement, begins to develop
compressive strength. However, if insufficient
time is allowed to fully pump the cement, it will
be necessary to drill the cement remaining in
the casing string. Remedial operations such as
this are very costly. Conversely, cements that
are successfully placed, but require considerable
time to cure, consume valuable rig time, which
is also quite costly. Laboratory tests should
be conducted under simulated reservoir conditions
to examine the actual thickening time of the slurry.
The OFITE HTHP Consistometer was specifically
engineered to determine the thickening time of
well cements under simulated downhole pressures
and temperatures.
Method of Operation:
A cement is mixed and poured into the slurry
cup assembly. The slurry cup is placed into the
test vessel and pressure is increased via an air-driven
hydraulic pump. A PID temperature controller governs
an internal heater, which maintains the necessary
temperature profile, while a magnetic drive mechanism
rotates the slurry cup assembly at 150 RPM. A
potentiometer controls an output voltage, which
is directly proportional to the amount of torque
the cement exerts upon an API-approved paddle.
A multi-channel, paperless graphic recorder registers
cement consistency and temperature as a function
of time. Temperature and consistency are digitally
displayed on screen and saved to a disk for later
analysis.
Features and Specifications:
- Maximum operating temperature of 600°F / 400°F
- Maximum pressure of 40,000 PSI / 25,000 PSI
- Digital temperature controller, 1° resolution
- 4,000-watt internal heater (5,000-watt available)
- Pressure indicator resolution is 100 PSI and incorporates high and low-pressure alarms
- Slurry cup rotational speed is 150 RPM
- Pressure generated via an air-driven hydraulic pump
- Slurry cup constructed of 316 stainless steel and incorporates an expansion chamber
- Drive table is rotated with a magnetic drive
- External cooling jacket aids cooling of test cell
- Electronic timer with alarm, elapsed 0.1 minute resolution
- Deadweight calibration unit included
- Temperature, pressure, and consistency alarms provide automatic shutdown
- Safety head with rupture disk are provided
- Unit is fully capable of testing cements in strict accordance to the guidelines as stated within API Specification 10
Instrument Requirements:
- Air/Nitrogen supply (100 - 120 PSI)
- Water supply for cooling (40 PSI)
- Water drain
- 230-Volt, 50/60 Hz, 25-Amp electrical power supply
Size: 66" × 36" × 32" (168 × 91 × 81 cm)
Weight: 1,400 lb (635.6 kg)
Crated Size: 74" × 44" × 40" (188 × 112 × 102
cm)
Crated Weight: 1,600 lb (726.4
kg)
Diagram of 120-521 slurry cup.
Components: -
120-00
OFITE MODEL 100 HTHP CONSISTOMETER, 25,000 PSI, 400°F, SINGLE CELL, 230 VAC, 50/60 HZ
-
120-05
OFITE MODEL 100 HTHP CONSISTOMETER, 25,000 PSI 400°F, DUAL CELL, 230 VAC, 50/60 HZ
-
120-10
OFITE MODEL 120 HTHP CONSISTOMETER, 40,000 PSI 600°F, SINGLE CELL, 230 VAC, 50/60 HZ
-
120-15
OFITE MODEL 120 HTHP CONSISTOMETER, 40,000 PSI 600°F, DUAL CELL, 230 VAC, 50/60 HZ
Optional: -
120-01
SPARE PARTS FOR ONE YEARS OPERATION FOR NO. 120-00, 25K CONSISTOMETER
-
120-02
SPARE PARTS FOR FOR TWO YEARS OPERATION FOR NO. 120-00
-
120-11
SPARE PARTS FOR ONE YEARS OPERATION FOR NO. 120-10, 40K CONSISTOMETER