Recording Atmospheric Consistometer
#120-80: 115-Volt
#120-80-1: 230-Volt
The Model 80 Recording Atmospheric Consistometer
is utilized to condition cement slurries in accordance
with API Specification 10. Determination of rheological
properties, examination of free water content,
and evaluation of the API fluid loss test all
require that the cement slurry be conditioned
by an atmospheric consistometer. The OFITE Model
80 incorporates the same features as our Model
60 Atmospheric Consistometer and additionally,
measures and reports temperature and consistency
as a function of time via a paperless graphic
recorder.
Method of Operation:
A cement slurry is prepared according to the
procedures outlined within API Specification 10
and then placed within the slurry containers of
the Model 80 Recording Atmospheric Consistometer.
The slurry is typically stirred at 150 RPM by
an API-designed paddle and the temperature is
increased to the desired level. The temperature
is controlled by a microprocessor, which displays
the process temperature via a digital indicator.
Consistency, measured in Bearden Units (Bc), is
determined by measuring the deflection of a calibrated
spring. This deflection is created by the amount
of torque that the cement slurry exerts upon the
paddle and is a function of the consistency of
the cement. A potentiometer mechanism generates
an output voltage signal, which is directly proportional
to the consistency of the cement. The graphic
recorder transforms the output voltage signal
into Bearden Units of consistency, which is digitally
displayed and stored on disk for later analysis.
Features and Specifications:
- Operating temperatures to 200°F
- Multi-channel paperless graphic recorder measures
temperature and consistency of each container
- Unit operates at atmospheric pressure
- Microprocessor temperature controller
- Digitally displays process temperature
- Heat transfer fluid is circulated
- Heater wattage is 1,500
- Slurry container rotational speed is 150 RPM
- Dual sample container design
- Two alarms indicate termination of the test
- Cooling coils
- Stainless steel temperature bath
- Deadweight calibration unit
Instrument Requirements:
- Water supply for cooling
- Water drain
- 115-Volt, 50/60 Hz, 20-Amp
- 230-Volt, 50 Hz, 10-Amp
Size: 30" × 16" × 18" (76 × 41 × 46 cm)
Weight: 105 lb (47.7 kg)
Crated Size: 23" × 20" × 22" (58 × 51 × 56
cm)
Crated Weight: 170 lb (77.2 kg)
Components: -
120-80
RECORDING ATMOSPHERIC CONSISTOMETER, 120 VOLT, MODEL 80
-
120-80-1
RECORDING ATMOSPHERIC CONSISTOMETER, 230 VOLT, OFITE MODEL 80