|
Products
Cementing
Completions
Core Testing
Drilling Fluids
Aging
Cells
Balances
Blenders
Centrifuge
Corrosion
Rings
CST
Electrical
Stability
Filter
Presses
Hydrometers
Hygrometers
Kits,
Portable
Lubricity
Testers
Mixers
Ovens,
Roller
pH
Meters
Regulators
Resistivity
Retorts
Shale
Testing
Sticking
Tester
Stirrers
Thermocups
Viscometers
Lab Housing
Mud
Logging
Reagents
Reconditioned
Restaurant
Software
Stimulation/Frac
Supplies
Wastewater
What's New Shopping
Services
MSDS
Instructions
News
Login
Forms
Order
Form
Credit
Application
|
| Filter
Presses |
The OFITE low pressure filter press design features a cell body to hold the mud sample, a pressure inlet, and a base cap with screen and filter paper. Suitable for field and laboratory use, these units have become the industry standard for low pressure/low temperature filtration testing.
OFITE also manufactures other types of filter press units and inventories a full line of replacement and consumable parts. Stainless steel cases are available for most of the units. When several tests
must be run simultaneously, as in a laboratory environment, multi-units are available in either two, four, or six- cell designs. These multi-units come complete with manifolds and all necessary air hoses and bleed-off valves. The field portable units are supplied with various pressurization assemblies and manifolds and rely mainly on carbon dioxide bulbs and nitrogen gas to provide pressure. The
American Petroleum Institute (API) recommends a standard 100 ± 1.0 psi (690 ± 6.9 kPa) cell pressure be applied within 30 seconds for a 30 minute test.
When high pressure and high temperature filtration measurements are required,
HTHP filter presses designed specifically for simulating down-hole conditions are recommended. Test temperatures for all models may exceed 200°F (93°C), provided a back-pressure receiver is used to collect the filtrate. The components of the OFITE
HTHP filter presses are fully interchangeable with those marketed by other manufacturers. Three different sizes are available to accommodate different requirements and preferences. The No. 170-00 series is a field portable unit with a 175 ml sample cell and a small power consumption consisting of two 200 Watt heaters. The test cell is encased in the heating jacket to ensure complete and uniform sample heating. Normally
CO2 bulbs are used to pressurize both the cell and back pressure receiver, however other pressurization options are available. The
171-50 style HTHP filter press features quick connect couplings for pressurization. It is also portable and may be ordered with a stainless steel case (No. 171-81).
Both of these filter presses are designed for test temperatures up to 350°F (176°C). The No. 171-00 series is equipped with a 500 ml sample cell and four 200 Watt heaters for temperatures above 350°F (176°C) making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures. All
HTHP units may be ordered with 115 Volt or 230 Volt power requirements. A multi-unit laboratory model is available and may be custom designed to your specifications. A wide variety of accessories and replacement parts are also available.
|
|
| Low
Pressure |
 |
140-00 |
Wall
Mount Filter Press - Basic |
 |
140-10 |
Wall
Mount Filter Press with CO2 Pressure Assembly |
 |
140-20 |
Bench
Mount Filter Press - Basic |
 |
140-30 |
Bench
Mount Filter Press with CO2 Pressure Assembly |
 |
140-31 |
Bench
Mount Filter Press with Regulator (143-00) and Hose |
 |
140-35 |
Bench
Mount Filter Press with Nitrogen Manifold and Cylinder |
 |
140-40 |
4-Unit
Laboratory Model Filter Press |
| |
140-41 |
4-Unit
Filter Press, Model 12BL-4 |
 |
140-42 |
6-Unit
Filter Press, Model 12BL-6 |
 |
140-43 |
2-Unit
Filter Press, Model 12BL-2 |
 |
140-50 |
6-Unit
Laboratory Model Filter Press |
 |
140-60 |
Complete
Half Area Filter Press |
 |
140-75 |
Bench
Mount Filter Press with Dead Weight Hydraulic Assembly |
 |
140-80 |
“Filter
Rite” Low Pressure Filter Press |
 |
142-53 |
Model MB
Filter Press with CO2 Assembly |
 |
144-10 |
Wall
Mount Filter Press in Stainless Steel Case |
 |
162-71 |
Kit
Sized Full Area Filter
Press with “Stabilizer” Regulator |
| HTHP |
 |
170-00 |
Complete
HTHP Filter Press, 175 ml, 1500 psi, 115 Volt, 400 Watt
|
 |
170-00-3 |
HTHP
Filter Press w/Single Capped Cell, N2, 175 ml, 115 Volt |
 |
170-00-4 |
4-Unit
HTHP Filter Press |
| |
170-01 |
Complete
HTHP Filter Press, 175 ml, 1500 psi, 230 Volt, 400 Watt |
| |
170-01-3 |
HTHP
Filter Press w/Single Capped Cell, N2, 175 ml, 230 Volt |
 |
170-50 |
Dynamic
HTHP Filter Press, 115 Volt |
| |
170-50-1 |
Dynamic
HTHP Filter Press, 230 Volt |
 |
171-00-C |
Complete
HTHP Filter Press, 500 ml, 2000 psi, 115 Volt, 800 Watt |
| |
171-01-C |
Complete
HTHP Filter Press, 500 ml, 2000 psi, 230 Volt, 800 Watt |
 |
171-50 |
Complete
Model MB HTHP Filter Press, 1500 psi, 115 Volt |
| |
171-50-4 |
Model
MB 4-Unit HTHP Filter Press, 115 Volt |
| |
171-51 |
Complete
Model MB HTHP Filter Press, 1500 psi, 230 Volt |
| Cement |
| |
170-00-2 |
HTHP
Filter Press for Cement Testing, 175 ml, 2000 psi, Double
Capped Cell,
N2 Manifold, 115 Volt |
| |
170-01-2 |
HTHP
Filter Press for Cement Testing, 175 ml, 2000 psi, Double
Capped Cell,
N2 Manifold, 230 Volt |
| |
170-00-5 |
HTHP
Filter Press 175 ml, Double End, CO2, 115 Volt |
| |
170-01-5 |
HTHP
Filter Press 175 ml, Double End, CO2, 230 Volt |
| |
171-03 |
HTHP
Filter Press for Cement Testing, 500 ml, 2000 psi, Double
Capped Cell,
N2 Manifold, 115 Volt |
| |
171-04 |
HTHP
Filter Press for Cement Testing, 500 ml, 2000 psi, Double
Capped Cell,
N2 Manifold, 230 Volt |
| Permeability
Plugging Tester |
| |
171-84 |
Permeability
Plugging Tester (PPT), 4000 psi, 115 Volt |
| |
171-84-01 |
Permeability
Plugging Tester (PPT), 4000 psi, 230 Volt |
 |
171-90 |
Permeability
Plugging Tester (PPT), 2000 psi, 115 Volt |
| Accessories |
 |
170-33 |
Cell
Cap Removal Tool |
 |
170-40 |
Carrying
Tool for HTHP Cell |
 |
171-23 |
TC
Safety Pin with Laynard |
|
|
|